ITEM DESCRIPTION
AREA
Displays currently defined Motion Detection area.
When an area is selected from the list, its defined area gets displayed
and highlighted in viewer window. Up to 3 motion detection area can
be defined.
Show Selected Area
When this is checked, only the selected area gets displayed in viewer
window.
Caption Enter designation for each area.
Sensitivity
Sets sensitivity for detecting motions, “1” being the least sensitive and
“10” being the most sensitive. The user needs to configure this
according to their applications and circumstances.
Defining Motion Detection Area
1. Enter a designation in the caption bar, and set sensitivity.
2. Click “New” button.
3. A square with the designation you’ve just defined will appear in
viewer window.
4. The size of the square can be adjusted by clicking and dragging its
lower right corner, and the position can be adjusted by dragging the
square.
5. Click “Save” button once you are done defining the areas.